Problem solved


[Follow Ups] [Post Followup] [Dodge Power Wagon Forum]


Posted by Clint Dixo [172.70.35.50] on Monday, August 22, 2022 at 13:16:38 :

In Reply to: Sight Emergency. Paging Tom Petroff posted by Clint Dixon [172.70.178.151] on Saturday, August 20, 2022 at 18:12:28 :

After following the great instructions for checking the generator offered by Tom and Vaughn, I found that the generator ran very well like a motor when loosening the belt and applying power from the battery to the armature lead.

Further tests were performed both on and off the truck.

I ended up disassembling the generator, dressing the Mica between the contacts on the commutator and finishing this off with a pass with 600 grit sandpaper to remove the resulting burrs on the contacts and to clean up oxidation.