Posted by scott56 [172.68.132.62] on Monday, November 08, 2021 at 09:23:49 :
In Reply to: '48 amp. gauge issue posted by Dickie in Southwest Va. [172.69.62.44] on Monday, November 08, 2021 at 08:30:28 :
Wow, I did the same thing when I touched the wire shield around my temp gauge tube with a wrench and a hot spot. This, a few months after I had replaced the old tube and bulb with a new tube and bulb attached to the original gauge. The inner capillary tube was not damage but it eventually failed. I have some original amp meters and can check them out if you need to replace. I know right where they are in the garage.