Posted by Vaughn on July 23, 2000 at 12:58:43:
In Reply to: Wiring Help posted by Maurice on July 22, 2000 at 14:55:56:
This is for a WDX (6volt), I'm not sure if it is the same as the WC.
Generator has two wires: "F" and "A". Connect each one to the "FLD" and "ARM" terminals on the regulator. The "BAT" terminal on the regulator goes to the "+" side of the ammeter (I'm assuming the WC is a positive ground system, if it's not, connect to the "-" side).
Polarizing
Connect battery up
Using a 1/16 inch wire, 8 inches long, hold one end to the "BAT" terminal. Using the other end, touch the "ARM" terminal for about two seconds. Do not touch the "FLD" terminal or other metal with the wire! Your now ready to go!!