Re: Repower starter question


[Follow Ups] [Post Followup] [Dodge Power Wagon Forum]


Posted by Paul (in NY) [173.245.52.145] on Thursday, October 13, 2016 at 08:18:10 :

In Reply to: Repower starter question posted by Don in Missouri [172.68.58.144] on Wednesday, October 12, 2016 at 22:50:10 :

I have not used a SAE #3 on PW. But the following may give you some insight. When using The Cummins/Dodge Bell/NV-4500 the starter mounts on the driver side. The entire engine/tranny must be moved .625" towards the passenger side to clear the starter with the saginaw PS Box. When using the Cummins/GM Bell/ GM-NV-4500, the starter mounts on the passenger side. Lots of room, no clearance issues. I imagine the SAE #3 with starter on the drivers side would also have issues with PS Box.

Paul

Paul



Follow Ups:



Post a Followup

Name:
E-Mail:
Subject:
Message:
Optional Link
URL:
Title:
Optional Image Link
URL:


This board is powered by the Mr. Fong Device from Cyberarmy.com