Re: OT outdoor water furnace


[Follow Ups] [Post Followup] [Dodge Power Wagon Forum]


Posted by Kevin in Ohio [50.102.56.145] on Tuesday, November 26, 2013 at 09:06:16 :

In Reply to: OT outdoor water furnace posted by junoir copey [100.43.114.58] on Tuesday, November 26, 2013 at 08:38:15 :

Like Tim said, a little more info needed. That said here are a few options but it depends on what you have.

You can run a mixing valve as pictured here. I have one of these that feed the radiant floor heat in my garage floors as you don't want the water too hot going in. Installed a temp guage so I can dial it in.

Hot water comes from bottom, cold from top. You can see the guage where it has been mixed on the left. There are 2 zones in the garage that I can keep at different temps with thermastats. When the thermastat calls for heat, Their pump kicks on.

My outdoor wood boiler's circulator pump runs constant as I heat my domestic hot water with a sidearm heat exchjanger. Boiler is set to keep water at 178 as a low, 185 at the high.