Posted by Vaughn on Thursday, July 02, 2009 at 10:08:58 :

In Reply to: VAUGHN - How do I check the two fields in the gen for grounding posted by Bob Stopka on Wednesday, July 01, 2009 at 19:26:47 :

There is a small wire that connects the two fields and it lays on the gen. housing. Check it for bare areas. Mine had worn through the insulation and it drove the charging to to about 45 amps. It took awhile to find that as the cause, but once I reinsulated it with electrical tape, the circuit was again normal and has been since. I suspect the problem is some place in the gen., if are sure you have no other shorts in the circuit. If the wire appears ok, take out the fields and look at the areas that lay against the housing.